Set or display the callsign and ssid range  of the node

Syntax: MY <CR>

The mycall command gives the callsign and the SSID range of the node. Example:

=> MY <CR>
mycall: DB0ODW, SSID’s: 0-7
=>

Syntax: MY <call> [<ssid1> <ssid2>] <CR>

The MYCALL-Command is used by the sysop to set up the callsign of the node. With the optional SSID’s a range may be defined by which the node can be connected. The SSID range must include the SSID’s of every port, no port SSID must be outside the SSID range defined by MYCALL.

Example:

M DB0ODW 0 7

The node callsign is set to DB0ODW. The node may be connected as DB0ODW-0 to DB0ODW-7. When the MYCALL is changed, this will affect only new QSO’s. Existing connections stay valid under the old callsign. The internode communication is re-initialized completely, since the change of the callsign needs to be forwarded to the network immediately.

 